GENERAL
The generator should be started at least once every seven
days and allowed to run at bast 30 minutes, if this cannot be
done and you must store the unit for more than 30 days, use
the following information as a guide to prepare it for storage.
LongTerm Storage instructions
It is importantto prevent gum deposits from forming in
essential fuel system parts, such as the carburetor, fuel filter,
fuel hose or tank during storage. Also, a]cohoi-bbnded fuels
(called gasoho], ethanol or methanol) can attract moisture,
which leadsto separation and formation of acids during
storage. Acidic fuel can damagethe fuel system of an engine
whib in storage.
Protect Fuel System
WARNING
_J Fueland its flammable and
vapors
are
extremely
explosive.
Fire or explosion can causesevere burns or
death.
WHENSTORINGFUELDREQUIPMENTWITHFUELIN TANK
* Storeawayfromfurnaces,stoves,waterheaters,clothesdryers
or otherappliancesthathavepilot light or otherignitionsource
becausetheycanignitefuelvapors.
WHENDRAININGFUEL
, TurngeneratorOFFandlet it coolat least2 minutesbefore
removingfuelcap.Loosencapslowlyto relievepressurein
tank.
, Drainfuel tankoutdoors.
* Keepfuelawayfromsparks,openflames,pilot lights,heat,and
otherignitionsources.
, DONOTlighta cigaretteor smoke.
FuelPreserver:
Fillthe fuel tank with fresh fuel allowing at bast 1.5" of tank
spacefor fuel expansion as shown on page8, when using a
fuel preserver cartridge with the fresh start fuel cap. If only
partially filled, air in the tank will promote fuel deterioration
during storage. Engineand fuel can be stored upto 6 months
with fuel preserver.
Check level of fuel preserver cartridge. Fuelpreserver is
dark in color.
If cartridge is almost empty or empty, replace with a new
fuel preserver cartridge following the instructions in Fresh
StarY Fuel Cap.
If fuel preserver is not used, remove all fuel from tank and
run engine until it stops from lack of fuel.
ChangeOil
While engine is still warm, drain oil from crankcase. Refill
with recommended grade. See ChangingEngine Oil.
Oil CylinderBore
Removespark plug and pour about 1 ounce (30ml) of
clean engine oil into the cylinder.
Install spark plug and crank slowly to distribute oil.
WARHIHG
_'_ Unintentionalsparking can result in fire or
_,¢ electric shock.
* NEVERcrankenginewith sparkplugremoved.
generator
1. Cleangenerator as outlined in Generator Cleaning.
2. Checkthat cooling air slots and openings on generator
are openand unobstructed.
Other Storage Tips
1. DO NOTstore fuel from one seasonto another unless it
has beentreated as described in Protect Fuel System.
2.
Replacefuel can if it starts to rust. Contaminatedfuel
will cause engine problems.
If possible, store unit indoors and cover it to give
protection from dust and dirt.
Coverunit with a suitable protective cover that does not
retain moisture.
WARHIHG
_ Storagecovers can be flammable.
* DONOTplacea storagecoveroverahot generator.
* Letequipmentcoolfor a sufficienttime beforeplacingthe
coveronthe equipment.
5. Store generator in clean, dry area.